CPS-EP3000 3000W 19-Inch Rack-Mount & Wall-Mount
- V programming with internal poti
- OCP & OVP
- Current Share Bus for N+1 parallel operation
- Sense Mode
- Current Monitoring
- Remote Shutdown
- Inhibit (Interlock)
- DC & AC Power Good Relay open/center/close
- Fan Monitoring
- Temperature OT alarm
- 6kW in a 2U & 10kW in a 3U subframe
- Hard mount in 90° steps
- Optional LAN Interface DIGI3201
CPS-EP3000
Model | CPS-EP3000(R2) | ||||||
Continuous Power | 3000W | ||||||
Nominal Input Voltage | 230Vac | ||||||
Input Voltage Range AC | 184-264Vac | ||||||
Input Voltage Range DC | 250-375Vdc | ||||||
Hold-up Time | 20ms | ||||||
Inrush Current AC | Electronic Inrush Limiter 14,6Arms | ||||||
Startautomatic | Softstart 100ms | ||||||
Vout | 12V | 24V | 36V | 48V | 72V | 110V | 220V |
Vout progr. with poti | 2-15V | 24-30V | 30-45V | 45-58V | 58-90V | 90-150V | 200-300V |
Aout | 200,0A | 125,0A | 83,0A | 62,5A | 41,6A | 27,2A | 13,6A |
Ripply & Boise mVpp | 35mV | 35mV | 35mV | 75mV | 100mV | 200mV | 400mV |
Effeciency | 94% | ||||||
Basic Load | Idling-proof | ||||||
Short Cicuit Protection | Continuous | ||||||
Cooling | Stepless controlled fans from EBM-Papst flow front-to-rear, Fan Fail message | ||||||
Dimensions | 84x126,4x444mm, 2U or 3U Embedded or hard mount in 90° steps | ||||||
Safety Standards | EN61010-1, EN61010-2-201, EN62368-1, EN60204-1, EN60950-1 | ||||||
Input- /Output Isolation | 3000Vac | ||||||
EMI | EN55032 class B and class A depending on models | ||||||
EMS | EN61000-6-2,3,4 | ||||||
MTBF | 500.000h | ||||||
Current Monitoring | Yes | ||||||
Inhibit (Interlock) | Yes | ||||||
DC Power Good Relay | Yes | ||||||
AC Power Good Relay | Yes | ||||||
Sense Compensation | Yes | ||||||
Remote Shutdown | Yes | ||||||
Continuous Mode | Yes | ||||||
Current Share Bus | Yes | ||||||
Fan Failure Monitor | Yes | ||||||
Temperature Monitor | Yes |