ESB101.LED.230Vac (for lighting)

ModelESB101.LED.230Vac(R2)
Limiting Peak current48A for Ton=300ms
Limiting RMS-value33,9A for Ton=300ms
Limiting Cycle Interval900ms (3x/minute)
Low Voltage DetectionToff=550ms
Input Voltage184 - 264Vac, 16 1/3 - 440Hz
Nominal voltage220 - 240Vac
AC Continuous Current16A
Power Consumption1,1W
Load capacity6000uF
ConnectorsSpring-type-terminal 0,5 - 6mm²
Ambient Opearting Temperature-40°C - +60°C no derating
CoolingNatural convection
Dimensions (WxHxD)36,5 x 62 x 110mm
Safety StandardsEN61010-1, EN61010-2-201, EN62368-1, EN60204-1, EN60950-1
ApprovalsUL508, CSA22.2, GOHST EAC
Special FeaturesTemperature protected (fuse)
 Fire protected
 Accuracy ±5%, independent from ambient temperature
 Capacitive loads
 Bypass circuit
 4000m / 13123 ft. above sea level



 

ESB101.LED.115Vac (for lighting)

ModelESB101.LED.115Vac(R2)
Limiting Peak current43A for Ton=500ms
Limiting RMS-value30,4A for Ton=500ms
Limiting Cycle Interval900ms (3x/minute)
Low Voltage DetectionToff=550ms
Input Voltage90 - 130Vac 16 1/3 - 440Hz 1PH
Nominal voltage110 - 120Vac
AC Continuous Current16A
Power Consumption2,2W
Load capacity10000uF
ConnectorsSpring-type-terminal 0,5 - 6mm²
Ambient Opearting Temperature-40°C - +60°C no derating
CoolingNatural convection
Dimensions (WxHxD)36,5 x 62 x 110mm
Safety StandardsEN61010-1, EN61010-2-201, EN62368-1, EN60204-1, EN60950-1
ApprovalsUL508, CSA22.2, GOHST EAC
Special FeaturesTemperature protected (fuse)
 Fire protected
 Accuracy ±5%, independent from ambient temperature
 Capacitive loads
 Bypass circuit
 4000m / 13123 ft. above sea level



 

ESB101.05UPS (for Inverters and sensitive power distribution)

ModelESB101.05UPS(R2)
Limiting Peak current5A for Ton=900ms
Limiting RMS-value3,5A for Ton=900ms
Limiting Cycle Interval900ms (3x/minute)
Low Voltage DetectionToff=1400ms
Input Voltage184 - 264Vac, 16 1/3 - 440Hz
Nominal voltage220 - 240Vac
AC Continuous Current16A
Power Consumption1,1W
Load capacity4000uF
ConnectorsSpring-type-terminal 0,5 - 6mm²
Ambient Opearting Temperature-40°C - +60°C no derating
CoolingNatural convection
Dimensions (WxHxD)36,5 x 62 x 110mm
Safety StandardsEN61010-1, EN61010-2-201, EN62368-1, EN60204-1, EN60950-1
Special FeaturesTemperature protected (fuse)
 Fire protected
 Accuracy ±5%, independent from ambient temperature
 Capacitive loads
 Bypass circuit
 4000m / 13123 ft. above sea level

 

ESB101.16

ModelESB101.16(R2)
Limiting Peak current16A for Ton=300ms
Limiting RMS-value11,3A for Ton=300ms
Limiting Cycle Interval900ms (3x/minute)
Low Voltage DetectionToff=500ms
Input Voltage184 - 264Vac, 16 1/3 - 440Hz 1PH
Nominal voltage220 - 240Vac
AC Continuous Current16A
Power Consumption1,1W
Load capacity1500uF
ConnectorsSpring-type-terminal 0,5 - 6mm²
Ambient Opearting Temperature-40°C - +60°C no derating
CoolingNatural convection
Dimensions (WxHxD)36,5 x 62 x 110mm
Safety StandardsEN61010-1, EN61010-2-201, EN62368-1, EN60204-1, EN60950-1
ApprovalsUL508, CSA22.2, GOHST EAC
Special FeaturesTemperature protected (fuse)
 Fire protected
 Accuracy ±5%, independent from ambient temperature
 Capacitive loads
 Bypass circuit
 4000m / 13123 ft. above sea level



 

ESB101.23

ModelESB101.23(R2)
Limiting Peak current23A for Ton=300ms
Limiting RMS-value16,3A for Ton=300ms
Limiting Cycle Interval900ms (3x/minute)
Low Voltage DetectionToff=500ms
Input Voltage184 - 264Vac, 16 1/3 - 440Hz 1PH
Nominal voltage220 - 240Vac
AC Continuous Current16A
Power Consumption1,1W
Load capacity2000uF
ConnectorsSpring-type-terminal 0,5 - 6mm²
Ambient Opearting Temperature-40°C - +60°C no derating
CoolingNatural convection
Dimensions (WxHxD)36,5 x 62 x 110mm
Safety StandardsEN61010-2-201, EN62368-1, EN60204-1, EN60950-1
ApprovalsUL508, CSA22.2, GOHST EAC
Special FeaturesTemperature protected (fuse)
 Fire protected
 Accuracy ±5%, independent from ambient temperature
 Capacitive loads
 Bypass circuit
 4000m / 13123 ft. above sea level



 

ESB101.23S

ModelESB101.23S(R2)
Limiting Peak current23A for Ton=500ms
Limiting RMS-value16,3A for Ton=500ms
Limiting Cycle Interval1400ms (3x/minute)
Low Voltage DetectionToff=800ms
Input Voltage184 - 264Vac, 16 1/3 - 440Hz 1PH
Nominal voltage220 - 240Vac
AC Continuous Current16A
Power Consumption1,1W
Load capacity2000uF
ConnectorsSpring-type-terminal 0,5 - 6mm²
Ambient Opearting Temperature-40°C - +60°C no derating
CoolingNatural convection
Dimensions (WxHxD)36,5 x 62 x 110mm
Safety StandardsEN61010-1, EN61010-2-201, EN62368-1, EN60204-1, EN60950-1
ApprovalsUL508, CSA22.2, GOHST EAC
Special FeaturesTemperature protected (fuse)
 Fire protected
 Accuracy ±5%, independent from ambient temperature
 Capacitive loads
 Bypass circuit
 4000m / 13123 ft. above sea level



 

ESB101.23S.115Vac

ModelESB101.23S.115Vac(R2)
Limiting Peak current23A for Ton=500ms
Limiting RMS-value16,3A for Ton=500ms
Limiting Cycle Interval1400ms (3x/minute)
Low Voltage DetectionToff=900ms
Input Voltage90 - 130Vac, 16 1/3 - 440Hz 1PH
Nominal voltage110 - 120Vac
AC Continuous Current16A
Power Consumption2,2W
Load capacity4000uF
ConnectorsSpring-type-terminal 0,5 - 6mm²
Ambient Opearting Temperature-40°C - +60°C no derating
CoolingNatural convection
Dimensions (WxHxD)36,5 x 62 x 110mm
Safety StanndardsEN61010-1, EN61010-2-201, EN62368-1, EN60204-1, EN60950-1
ApprovalsUL508, CSA22.2, GOHST EAC
Special FeaturesTemperature protected (fuse)
 Fire protected
 Accuracy ±5%, independent from ambient temperature
 Capacitive loads
 Bypass circuit
 4000m / 13123 ft. above sea level



 

ESB101.33

ModelESB101.33(R2)
Limiting Peak current33A for Ton=300ms
Limiting RMS-value23,3A for Ton=300ms
Limiting Cycle Interval900ms (3x/minute)
Low Voltage DetectionToff=800ms
Input Voltage184 - 264Vac, 16 1/3 - 440Hz 1PH
Nominal voltage220 - 240Vac
AC Continuous Current16A
Power Consumption1,1W
Load capacity4000uF
ConnectorsSpring-type-terminal 0,5 - 6mm²
Ambient Opearting Temperature-40°C - +60°C no derating
CoolingNatural convection
Dimensions (WxHxD)36,5 x 62 x 110mm
Safety StandardsEN61010-1, EN61010-2-201, EN62368-1, EN60204-1, EN60950-1
ApprovalsUL508, CSA22.2, GOHST EAC
Special FeaturesTemperature protected (fuse)
 Fire protected
 Accuracy ±5%, independent from ambient temperature
 Capacitive loads
 Bypass circuit
 4000m / 13123 ft. above sea level