OSW00751
- 1phase Fixed Output baseplate cooled (not required for full operation)
- low ripple & noise for sensitive loads like professional audio, sensors, measuring & control euqipment
OSW00751
Model | OSW00751 | ||||
Power | 75W | ||||
Nominal AC Input | 100... 240Vac | ||||
Input Range AC | 90... 265Vac | ||||
Input Range DC | 110... 375Vdc | ||||
Input Frequency | 47... 63Hz | ||||
Hold-Up Time | 40ms | ||||
Inrush Current Protection | NTC <32A | ||||
Autostart | Soft start 50ms | ||||
Output Voltage | 5V | 9V | 12V | 15V | 24V |
Adjust Range Vout | 4,9... 5,5V | 8,6... 9,9V | 11,4... 13,2V | 14,3... 16,5V | 22,5... 28,5V |
Ripple & Noise mVpp | 15mV | 15mV | 20mV | 20mV | 50mV |
Nominal Output Current | 7,5A | 7,6A | 6A | 5A | 3,2A |
Power Boost <=60°C/60s | 9A | 9,1A | 7,2A | 6A | 3,8A |
Stability at Load Switch | ±0,1% | ±0,5% | ±0,3% | ±0,2% | ±0,1% |
Transient Time | < 1ms | ||||
Efficiency | 90% | ||||
Basic load | Idling-proof | ||||
Short Circuit Protection | Continuous | ||||
Ambient Operation Temperature | -20°C... +70°C | ||||
Cooling | Natural convection | ||||
Temperature Monitoring | Upon request | ||||
Dimensions (WxHxD) | 100x91x45mm | ||||
IP-Range | Open frame | ||||
Safety IEC | EN60950-1 EN50178 EN60204-1 | ||||
Safety Class 1(A) | VDE0100 VDE0805 | ||||
Input to Output Isolation | 3000Vac | ||||
Climatic Class, Humidity | 3k3, 90% non condensing | ||||
EMI | EN55022B EN61000-3-2A | ||||
EMS | EN61000-6-2,3 | ||||
MTBF IEC61709 | 500000h | ||||
Power Good Relay | Upon request | ||||
Sense operation | Upon requst for 5V ±200mV | ||||
Features | Baseplate cooled power | ||||
Ordering options | Power good relay, sensing for 5Vdc model | ||||
Options | See datasheet |