HSW00751
Model | HSW00751(R2) | |||
Power | 75W | |||
Nominal AC Input | 100-240Vac | |||
Input Range AC | 90-264Vac | |||
Input Range DC | 110-375Vdc | |||
Hold-Up Time | 40ms | |||
Inrush Current Protection | NTC | |||
Autostart | Soft start | |||
Output Voltage | 5V | 12V | 15V | 24V |
Adjust Range Vout | 4,9-5,5V | 11,4-13,2V | 14,3-16,5V | 24,0-28,0V |
Ripple & Noise mVpp | 15mV | 20mV | 20mV | 50mV |
Nominal Output Current | 7,5A | 6,0A | 5,0A | 3,2A |
Efficiency | 90% | |||
Basic load | Idling-proof | |||
Short Circuit Protection | Continuous | |||
Cooling | Natural convection | |||
Dimensions (WxHxD) | 50x102x93,1mm | |||
Safety Standards | EN61010-1, EN61010-2-201, EN62368-1, EN60204-1, EN60950-1 | |||
Input to Output Isolation | 3000Vac | |||
EMI | EN55032 Klasse B, EN61000-6-3, EN61000-3-2 Klasse A | |||
EMS | EN61000-6-2 | |||
MTBF | 500.000h | |||
Power Good Relay | Yes | |||
Sense operation | Yes for 5V-model ±200mV |