Model | HSEUiREG10001(R2) | |||||||
Power | 1008W | |||||||
Nominal Input | 115/230Vac selector | |||||||
Input Range AC | 90-115Vac/184-264Vac | |||||||
Input Range DC | 250-375Vdc | |||||||
Hold-Up Time | 30ms | |||||||
Inrush Current Protection | Electronic Inrush Limiter 9,8Arms | |||||||
Autostart | Soft start | |||||||
Programmable Output Voltage | 0-18V | 0-30V | 0-50V | 0-90V | 0-130V | 0-180V | 0-240V | 0-400V |
Programmable Output Current | 0-50,0A | 0-42,0A | 0-25,0A | 0-14,0A | 0-9,5A | 0-7,0A | 0-5,3A | 0-3,2A |
Ripple & Noise mVss | 40mV | 40mV | 120mV | 150mV | 200mV | 300mV | 400mV | 400mV |
Efficiency | 90% | |||||||
Basic Load | Idling-proof | |||||||
Short Circuit Protection | Continuous | |||||||
Cooling | Controlled fan from EBM Papst (Germany) | |||||||
Dimensions (WxHxD) | 200x156x115mm | |||||||
Safety Standards | EN61010-1, EN61010-2-201, EN62368-1, EN60204-1, EN60950-1 | |||||||
Input to Output Isolation | 3000Vac | |||||||
EMI | EN55032 class B, EN61000-6-3 | |||||||
EMS | EN61000-6-2 | |||||||
MTBF | 400.000h | |||||||
Programming Interface Voltage | 0-5Vdc, 0-10Vdc, 0-20mA, 4-20mA | |||||||
Programming Interface Current | 0-5Vdc, 0-10Vdc, 0-20mA, 4-20mA | |||||||
Monitoring Interface Voltage | 0-5Vdc, 0-10Vdc | |||||||
Monitoring Interface Current | 0-5Vdc, 0-10Vdc | |||||||
Power Good Relay | Yes | |||||||
Sense Compensation | Yes | |||||||
Remote Shutdown | Yes | |||||||
Reference Voltage | Yes |