Specifications
- 3D-HD (3D Heat Dissipation) performs 360° mount in a 3-dimensional room
- 0-max. durrent & voltage programmable
- Current & Voltage Monitoring
- N+1 Parallel Operation
- Maste Slave Operation for synchronus programming
- Current Share Bus for equal power distribution
- Constant Current Mode & Constant Voltage mode
- Fuse Mode & Continuous Mode
- Sensing Compensation
- Remote Shutdown
- Inhibit (Interlock)
- Temperature Monitoring & Fan Fail Monitoring
- Aux +12V 500mA
- Optional Powersink for quick down programming
- 6KW in a 2U sub rack
- 10KW in a 3U sub rack
- Optional LAN Interface DIGI3201
CPS-i2000
Model | CPS-i2000(R2) | ||||
Continuous Power | 2000W | ||||
Nominal Input Voltage | 230Vac | ||||
Input Voltage Range AC | 184-264Vac | ||||
Input Voltage Range DC | 250-375Vdc | ||||
Hold-up Time | 30ms | ||||
Inrush Current AC | Electronic Inrush Limiter 14,Arms | ||||
Autostart | Soft start | ||||
Programmable Output Voltage | 0-18V | 0-30V | 0-60V | 0-90V | 0-150V |
Programmable Output Current | 0-165,0A | 0-100,0A | 0-50,0A | 0-33,0A | 0-20,0A |
Ripply & Boise mVpp | 35mV | 35mV | 75mV | 100mV | 200mV |
Effeciency | 94% | ||||
Basic Load | Idling-proof | ||||
Short Cicuit Protection | Continuous | ||||
Cooling | Stepless controlled fans from EBM-Papst (Germany) flow front-to-rear | ||||
Dimensions (WxHxD) | 126,4x84x444mm, 2U or 3U 19-Inch sub-rack or wallmount in 90° steps | ||||
Safety Standards | EN61010-1, EN61010-2-201, EN62368-1, EN60204-1, EN60950-1 | ||||
Input- /Output Isolation | 3000Vac | ||||
EMI | EN55032 class B and class A depending on models | ||||
EMS | EN61000-6-2,3,4 | ||||
MTBF | 419.000h | ||||
Interface Voltage Programming | 0-5Vdc, 0-10Vdc, 0-20mA, 4-20mA | ||||
Interface Current Programming | 0-5Vdc, 0-10Vdc, 0-20mA, 4-20mA | ||||
Interface Voltage Monitoring | 0-5Vdc, 0-10Vdc | ||||
Interface Current Monitoring | 0-5Vdc, 0-10Vdc | ||||
Inhibit (Interlock) | Yes | ||||
DC Power Good Relay | Yes | ||||
AC Power Good Relay | Yes | ||||
Sense Compensation | Yes | ||||
Remote Shutdown | Yes | ||||
Reference Voltage | Yes | ||||
Fuse Mode | Yes | ||||
Continuous Mode | Yes | ||||
Master Slave Mode | Yes | ||||
Current Share Bus | Yes | ||||
Fan Failure Monitor | Yes | ||||
Temperature Monitoring | Yes | ||||
Powersink | Optional available for quick down programming |