DISTRIBUTION

 

x

APW01502

  • 1phase Fixed Output baseplate cooled (not required for full operation)
  • Active inrush current protection
  • 8KV strange
  • 2+1 dc output

 

Product Information (PDF) Data Sheet (PDF)

 




APW01502

Model APW01502
Power 150W
Nominal Input AC 230Vac
Input range AC 184... 264Vac
Input range DC 250... 300Vdc
Input frequency 47... 63Hz
Hold-Up Time 50ms
Inrush Current Protection < 24Apeak / 17Arms electronic protection ±6%
Auto-start Soft start 20ms
Output voltage V1 + 12V + 15V  
Output voltage V2 - 12V - 15V  
Output voltage V3 + 24V + 30V U1 and U2 connectable
Adjust range V1 & V2 ±10%
Ripple mVpp V1 15mV 15mV  
Ripple mVpp V2 15mV 15mV  
Ripple mVpp V3  20mV
Output current I1 12A 10A  
Output current I2 12A 10A  
Output current I3 6,25A 5A  U1 and U2 connectable
Power boost 60s 180W
Stability Load switch ±1%
Transient time < 1ms
Efficiency 89%
Basic load Idling-proof
Short Circuit Protection Continuous
Ambient Operation Temperature -20°C... +70°C
Cooling Natural convection & baseplate cooled power
Temperature monitoring yes
Dimensions (WxHxD) 126x51x177mm
IP Rated IP20
Safety norm CSA UL CE according to IEC60950-1
Safety IEC EN60950-1 EN50178 EN60204-1
Safety class 1(A) VDE0100 VDE0805
Input to Output Isolation 3000Vac
Climatic Class, Humidity 3k3, 90% non condensing
EMI EN55022B EN61000-3-2A
EMS EN61000-6-2,3
MTBF IEC61709 450000h
Remote Shutdown Yes
Features 8KV/2.5kHz input transient protection
Ordering options Protective coating
Options See datasheet